Symptoms: Second speaker has scratchy sound, and cuts out
|
|
when adjusting volume.
|
|
|
|
Cure: Requires replacement of potentiometer, or alternatively
|
|
use of contact cleaner.
|
|
|
|
Identical (note: untested) pot appears to be a 10K 2 gang logarithmic
|
|
pot, manufacturer id: PDB182-K425K-103A
|
|
(Bourns).
|
|
|
|
Detailed description:
|
|
10k Ohm 2 Gang Logarithmic Panel Mount Potentiometer None 1 Kierros Carbon 0.06W PC Pins
|
|
|
|
|