@ -0,0 +1,40 @@ |
|
|
|
|
|
there are o2 sensors |
|
|
|
|
|
|
|
|
|
|
|
o2-a1 |
|
|
|
|
|
o2-a2 |
|
|
|
|
|
o2-a3 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
first sensor type is a two pin model. this outputs a uA current. |
|
|
|
|
|
there is a 2nd type (same o2 sensor above) but three pins. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
my guess is that 1 and 3 are power pins, 2 is signal |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
two pin model is replacable on dkey with sgx-40x |
|
|
|
|
|
uA current is near identical |
|
|
|
|
|
|
|
|
|
|
|
three pin model is replacable with ec410 though that is $30 more. |
|
|
|
|
|
|
|
|
|
|
|
Save $30 by hacking the three pin board (which is near identical) to be |
|
|
|
|
|
the two pin model. |
|
|
|
|
|
|
|
|
|
|
|
Making a foshw vers of these boards is trivial |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
There is a problem with electrochemical gas sensors. some of the main brands |
|
|
|
|
|
(alphasense, and citicel) only supply to OEM. The OEM doesn't easily supply replacements (i.e. honeywell). |
|
|
|
|
|
i will have to search some more. |
|
|
|
|
|
|
|
|
|
|
|
in any case, this is left to the consumer to either gamble on a $150 seller in IL, or buy the $40 china option. |
|
|
|
|
|
people will go to china every time. |
|
|
|
|
|
|
|
|
|
|
|
because there is no official distributor that resells the products, consumers get shafted. |
|
|
|
|
|
this is a shitty move by the companies. |
|
|
|
|
|
|
|
|
|
|
|
there are some options on dkey, but may not be 1:1 compatible (depends on the sensor). |
|
|
|
|
|
more testing on output needed |
|
|
|
|
|
|
|
|
|
|
|
why can't we just have official distributors instead of dealing with the OEM nonsense. mafia system. |